| Line 6: | Line 6: |
| 1. Plug in PDE cable into the serial port 1. Select Stocktake -> Pre-Record Stocktake Quantities |
1. In Control, select Stock -> Stocktake -> Record Pre-Stocktake Quantities |
| Line 11: | Line 10: |
| 1. Select "Clear data on PDE" to ensure it is blank when you first start. 1. Select on PDE unit "Collect Count = 1" 1. Start Scanning all items in the store 1. '''Select the icon PDE on your desktop (it allows the server to talk to the PDE unit)''' |
1. On PDE, select "Clear data on PDE" -> "Count File" to ensure it is blank when you first start. 1. On PDE, select unit "Collect Count = 1" 1. Start scanning all items in the store 1. '''On computer desktop, double-click on the "PDE" icon (it allows the server to talk to the PDE unit)''' |
| Line 16: | Line 15: |
| 1. In Control, select Stocktake -> PDE Stocktake Operations -> Retrieve Counts from PDE. | |
| Line 17: | Line 17: |
| 1. Select Stocktake -> PDE Stocktake Operations -> Retrieve Counts from PDE 1. A file name will be displayed on the screen. Press <enter> to select this file name. |
1. In Control, A file name will be displayed on the screen. Press <enter> to select this file name. |
| Line 21: | Line 20: |
| 1. Stocktake -> Generate Stocktake counts (although i think this happens automatically) 1. Print a Variance Report. When you are happy with your variance report... 1. Select -> Stocktake -> Generate Stocktake Adjustments - This will finalise the stock. |
1. Wait for 1 minute for counts to be processed. 1. In Control, select Stock -> Stocktake -> Stocktake Variance Report. This will show all variances between quantity in computer and quantity on shelves. 1. When satisfied with variance report, select -> Stocktake -> Generate Stocktake Adjustments - This will finalise the stock. |
| Line 25: | Line 25: |
| ["CategoryPDE"] | . ["CategoryPDE"] |
USING ABE AND A PDE STOCKTAKING UNIT
Here are some instructions to use the PDE when doing a stocktake:
In Control, select Stock -> Stocktake -> Record Pre-Stocktake Quantities
- Assume Recorded but not counted items are zero = Y
- Select the other options as applicable.
- Turn on the PDE unit.
On PDE, select "Clear data on PDE" -> "Count File" to ensure it is blank when you first start.
- On PDE, select unit "Collect Count = 1"
- Start scanning all items in the store
On computer desktop, double-click on the "PDE" icon (it allows the server to talk to the PDE unit)
- Plug in the PDE unit when ready to download
In Control, select Stocktake -> PDE Stocktake Operations -> Retrieve Counts from PDE.
- On PDE, select "Upload Counts"
In Control, A file name will be displayed on the screen. Press <enter> to select this file name.
- "Do you wish to import" = Y
- Once the system has imported, you should DELETE the data from the PDE unit
- Wait for 1 minute for counts to be processed.
In Control, select Stock -> Stocktake -> Stocktake Variance Report. This will show all variances between quantity in computer and quantity on shelves.
When satisfied with variance report, select -> Stocktake -> Generate Stocktake Adjustments - This will finalise the stock.
- ["CategoryPDE"]