There is a BHT BASIC compiler, (30 day trial period), located in the knowledge database hardware/pde/denso/bhtdev4t/BASIC/setup.exe. Need to remember to compile program as a BASIC 3.6 and to turn off warnings about undefined variables. Other wise just refer to the manual – also located in the knowledge database. Once compiled this should create a ccpde.pd3 file. There is a BHT BASIC compiler, (30 day trial period), located in the knowledge database hardware/pde/denso/bhtdev4t/BASIC/setup.exe. Need to remember to compile program as a BASIC 3.6 and to turn off option to causes errors for undefined variables. Other wise just refer to the manual – also located in the knowledge database. Once compiled this should create a ccpde.pd3 file.
Line 6: Line 6:
    ccpde here. To download the program onto the PDE Unit hold down SF, 1 and PW keys at the same time to get the System Menu.

You may need to setup the communication setting of the PDE unit first.

 . 4:SET SYSTEM
  . -> 5:COMMUNICATIONS
   . -> 2:CONNECTOR
    . -> 1:PARAMETER - should be set to
     . 1:TRANSMIT SPEED : 19200
     . 2:PARITY BIT: N
     . 3:DATA 8
     . 4:STOP 1
   . -> 3:COM PORT
    . 1:BASIC – Connector
    . 2:SYSTEM MODE – Connector
   . -> 4:PROTOCAL TYPE
    . 2:BHT-IR Protocol
To download the CCPDE program press 2:DOWNLOAD -> 1:FILE and then on the PC send the CCPDE.PD3 file using TSR-tu3a (located in knowledge database) transfer Utility (don’t forget to set the communication Parameters to 19200,N,8,1).

After the program is downloaded you could call 1:EXECUTE PROGRAM then CCPDE.PD3 or just turn the unit off and back on again will start the CCPDE program giving the following Menu.

 . 1.COLLECT
 . 2.COLLECT COUNT = 1
 . 3.UPLOAD COUNTS
 . 4.DOWNLOAD MASTERFILE
 . 5.DELETE MENU
----
 ["CategoryPDE"]

Updating CCPDE program for Denso

The CCPDE program is a program that runs in BHT BASIC, the source file resides in the std/pde directory called ccpde.src.

There is a BHT BASIC compiler, (30 day trial period), located in the knowledge database hardware/pde/denso/bhtdev4t/BASIC/setup.exe. Need to remember to compile program as a BASIC 3.6 and to turn off option to causes errors for undefined variables. Other wise just refer to the manual – also located in the knowledge database. Once compiled this should create a ccpde.pd3 file.

To download the program onto the PDE Unit hold down SF, 1 and PW keys at the same time to get the System Menu.

You may need to setup the communication setting of the PDE unit first.

  • 4:SET SYSTEM
    • -> 5:COMMUNICATIONS

      • -> 2:CONNECTOR

        • -> 1:PARAMETER - should be set to

          • 1:TRANSMIT SPEED : 19200
          • 2:PARITY BIT: N
          • 3:DATA 8
          • 4:STOP 1
      • -> 3:COM PORT

        • 1:BASIC – Connector
        • 2:SYSTEM MODE – Connector
      • -> 4:PROTOCAL TYPE

        • 2:BHT-IR Protocol

To download the CCPDE program press 2:DOWNLOAD -> 1:FILE and then on the PC send the CCPDE.PD3 file using TSR-tu3a (located in knowledge database) transfer Utility (don’t forget to set the communication Parameters to 19200,N,8,1).

After the program is downloaded you could call 1:EXECUTE PROGRAM then CCPDE.PD3 or just turn the unit off and back on again will start the CCPDE program giving the following Menu.

  • 1.COLLECT
  • 2.COLLECT COUNT = 1
  • 3.UPLOAD COUNTS
  • 4.DOWNLOAD MASTERFILE
  • 5.DELETE MENU


  • ["CategoryPDE"]