Line 6: Line 6:
To download the program onto the PDE Unit hold down SF, 1 and PW keys at the same time to get the System Menu.
Line 7: Line 8:
   4.DOWNLOAD MASTERFILE You may need to setup the communication setting of the PDE unit first.

                4:SET SYSTEM

                        -> 5:COMMUNICATIONS

                                -> 2:CONNECTOR

                                         -> 1:PARAMETER - should be set to

                                                      1:TRANSMIT SPEED : 19200

                                                      2:PARITY BIT: N

                                                      3:DATA 8 4:STOP 1 3:COM PORT 1:BASIC – Connector 2:SYSTEM MODE – Connector

4:PROTOCAL TYPE 2:BHT-IR Protocol

To download the CCPDE program press 2:DOWNLOAD -> 1:FILE and then on the PC send the CCPDE.PD3 file using TSR-tu3a (located in knowledge database) transfer Utility (don’t forget to set the communication Parameters to 19200,N,8,1).

After the program is downloaded you could call 1:EXECUTE PROGRAM then CCPDE.PD3 or just turn the unit off and back on again will start the CCPDE program giving the following Menu.

1.COLLECT 2.COLLECT COUNT = 1 3.UPLOAD COUNTS 4.DOWNLOAD MASTERFILE 5.DELETE MENU

Updating CCPDE program for Denso

The CCPDE program is a program that runs in BHT BASIC, the source file resides in the std/pde directory called ccpde.src.

There is a BHT BASIC compiler, (30 day trial period), located in the knowledge database hardware/pde/denso/bhtdev4t/BASIC/setup.exe. Need to remember to compile program as a BASIC 3.6 and to turn off option to causes errors for undefined variables. Other wise just refer to the manual – also located in the knowledge database. Once compiled this should create a ccpde.pd3 file.

To download the program onto the PDE Unit hold down SF, 1 and PW keys at the same time to get the System Menu.

You may need to setup the communication setting of the PDE unit first.

  • 4:SET SYSTEM
    • -> 5:COMMUNICATIONS

      • -> 2:CONNECTOR

        • -> 1:PARAMETER - should be set to

          • 1:TRANSMIT SPEED : 19200 2:PARITY BIT: N 3:DATA 8 4:STOP 1 3:COM PORT 1:BASIC – Connector 2:SYSTEM MODE – Connector

4:PROTOCAL TYPE 2:BHT-IR Protocol

To download the CCPDE program press 2:DOWNLOAD -> 1:FILE and then on the PC send the CCPDE.PD3 file using TSR-tu3a (located in knowledge database) transfer Utility (don’t forget to set the communication Parameters to 19200,N,8,1).

After the program is downloaded you could call 1:EXECUTE PROGRAM then CCPDE.PD3 or just turn the unit off and back on again will start the CCPDE program giving the following Menu.

1.COLLECT 2.COLLECT COUNT = 1 3.UPLOAD COUNTS 4.DOWNLOAD MASTERFILE 5.DELETE MENU