Differences between revisions 7 and 16 (spanning 9 versions)
Revision 7 as of 2006-05-23 00:28:01
Size: 1526
Editor: sweetums
Comment:
Revision 16 as of 2009-12-16 05:54:02
Size: 2215
Editor: JonCo
Comment:
Deletions are marked like this. Additions are marked like this.
Line 1: Line 1:
## page was renamed from updating ccpde
Line 2: Line 3:
The CCPDE program is a program that runs in BHT BASIC, the source file resides in the std/pde directory called ccpde.src.
Line 3: Line 5:
The CCPDE program is a program that runs in BHT BASIC, the source file resides in the std/pde directory called ccpde.src. There is a BHT BASIC compiler, (30 day trial period), located in the knowledge database hardware/pde/denso/bhtdev4t/BASIC/setup.exe. Need to remember to compile program as a BASIC 3.6 and to turn off option to causes errors for undefined variables. Other wise just refer to the manual – also located in the knowledge database. Once compiled this should create a ccpde.pd3 file.
Line 5: Line 7:
There is a BHT BASIC compiler, (30 day trial period), located in the knowledge database hardware/pde/denso/bhtdev4t/BASIC/setup.exe. Need to remember to compile program as a BASIC 3.6 and to turn off option to causes errors for undefined variables. Other wise just refer to the manual – also located in the knowledge database. Once compiled this should create a ccpde.pd3 file. To download the program onto the PDE Unit hold down SF, 1 and PW keys at the same time to get the System Menu.
Line 7: Line 9:
  To download the program onto the PDE Unit hold down SF, 1 and PW keys at the same time to get the System Menu.
 
Line 11: Line 10:
  4:SET SYSTEM  ->    5:COMMUNICATIONS  -> 2:CONNECTOR  -> 1:PARAMETER   - should be set to  1:TRANSMIT SPEED : 19200
2:PARITY BIT: N
3:DATA 8
4:STOP 1
-> 3:COM PORT
1:BASIC – Connector
2:SYSTEM MODE – Connector
 
-> 4:PROTOCAL TYPE  2:BHT-IR Protocol
 
To download the CCPDE program press 2:DOWNLOAD -> 1:FILE and then on the PC send the CCPDE.PD3 file using TSR-tu3a (located in knowledge database) transfer Utility (don’t forget to set the communication Parameters to 19200,N,8,1).   

 .
4:SET SYSTEM
  .
-> 5:COMMUNICATIONS
   .
-> 2:CONNECTOR
    .
-> 1:PARAMETER - should be set to
     .
1:TRANSMIT SPEED : 19200
     . 2:PARITY BIT: N
     . 3:DATA 8
     . 4:STOP 1
   . -> 3:COM PORT
    . 1:BASIC – Connector
    . 2:SYSTEM MODE – Connector
   . -> 4:PROTOCOL TYPE
    .
2:BHT-IR Protocol
==== Important note: ====
==== Turn the unit over, if the serial number ends in 04xxx, you will encounter serveral problems. First of all, TSR-tu3a will not be able to send ANYTHING. This is because the last 5 digits of the serial number is used as the BHT-Ir ID. If it starts with 04, this has a special meaning to the communications (EOT) and it gets interpreted as such. If the unit has a serial number ending in 04xxx, go into 4:PROTOCOL TYPE -> 2:BHT-Ir Protocol and enter a different number, such as 14xxx. You will be able to proceed as normal. ====

To download the CCPDE program press 2:DOWNLOAD -> 1:FILE and then on the PC send the CCPDE.PD3 file using TSR-tu3a (located in knowledge database) transfer Utility (don’t forget to set the communication Parameters to 19200,N,8,1).
Line 30: Line 29:
 
 
1.COLLECT
2.COLLECT COUNT = 1
3.UPLOAD COUNTS
4.DOWNLOAD MASTERFILE
5.DELETE MENU

 . 1.COLLECT
 . 2.COLLECT COUNT = 1
 . 3.UPLOAD COUNTS
 . 4.DOWNLOAD MASTERFILE
 . 5.DELETE MENU
----
 . ["CategoryPDE"]

Updating CCPDE program for Denso

The CCPDE program is a program that runs in BHT BASIC, the source file resides in the std/pde directory called ccpde.src.

There is a BHT BASIC compiler, (30 day trial period), located in the knowledge database hardware/pde/denso/bhtdev4t/BASIC/setup.exe. Need to remember to compile program as a BASIC 3.6 and to turn off option to causes errors for undefined variables. Other wise just refer to the manual – also located in the knowledge database. Once compiled this should create a ccpde.pd3 file.

To download the program onto the PDE Unit hold down SF, 1 and PW keys at the same time to get the System Menu.

You may need to setup the communication setting of the PDE unit first.

  • 4:SET SYSTEM
    • -> 5:COMMUNICATIONS

      • -> 2:CONNECTOR

        • -> 1:PARAMETER - should be set to

          • 1:TRANSMIT SPEED : 19200
          • 2:PARITY BIT: N
          • 3:DATA 8
          • 4:STOP 1
      • -> 3:COM PORT

        • 1:BASIC – Connector
        • 2:SYSTEM MODE – Connector
      • -> 4:PROTOCOL TYPE

        • 2:BHT-IR Protocol

Important note:

Turn the unit over, if the serial number ends in 04xxx, you will encounter serveral problems. First of all, TSR-tu3a will not be able to send ANYTHING. This is because the last 5 digits of the serial number is used as the BHT-Ir ID. If it starts with 04, this has a special meaning to the communications (EOT) and it gets interpreted as such. If the unit has a serial number ending in 04xxx, go into 4:PROTOCOL TYPE -> 2:BHT-Ir Protocol and enter a different number, such as 14xxx. You will be able to proceed as normal.

To download the CCPDE program press 2:DOWNLOAD -> 1:FILE and then on the PC send the CCPDE.PD3 file using TSR-tu3a (located in knowledge database) transfer Utility (don’t forget to set the communication Parameters to 19200,N,8,1).

After the program is downloaded you could call 1:EXECUTE PROGRAM then CCPDE.PD3 or just turn the unit off and back on again will start the CCPDE program giving the following Menu.

  • 1.COLLECT
  • 2.COLLECT COUNT = 1
  • 3.UPLOAD COUNTS
  • 4.DOWNLOAD MASTERFILE
  • 5.DELETE MENU


  • ["CategoryPDE"]

Updating_PDE_Software (last edited 2013-09-18 06:09:34 by localhost)