Differences between revisions 8 and 9
Revision 8 as of 2006-05-23 00:28:51
Size: 1508
Editor: sweetums
Comment:
Revision 9 as of 2006-05-23 00:31:30
Size: 1773
Editor: sweetums
Comment:
Deletions are marked like this. Additions are marked like this.
Line 2: Line 2:
The CCPDE program is a program that runs in BHT BASIC, the source file resides in the std/pde directory called ccpde.src.
Line 3: Line 4:
The CCPDE program is a program that runs in BHT BASIC, the source file resides in the std/pde directory called ccpde.src. There is a BHT BASIC compiler, (30 day trial period), located in the knowledge database hardware/pde/denso/bhtdev4t/BASIC/setup.exe. Need to remember to compile program as a BASIC 3.6 and to turn off option to causes errors for undefined variables. Other wise just refer to the manual – also located in the knowledge database. Once compiled this should create a ccpde.pd3 file.
Line 5: Line 6:
There is a BHT BASIC compiler, (30 day trial period), located in the knowledge database hardware/pde/denso/bhtdev4t/BASIC/setup.exe. Need to remember to compile program as a BASIC 3.6 and to turn off option to causes errors for undefined variables. Other wise just refer to the manual – also located in the knowledge database. Once compiled this should create a ccpde.pd3 file. To download the program onto the PDE Unit hold down SF, 1 and PW keys at the same time to get the System Menu.
Line 7: Line 8:
  To download the program onto the PDE Unit hold down SF, 1 and PW keys at the same time to get the System Menu.
 
Line 11: Line 9:
  4:SET SYSTEM  5:COMMUNICATIONS  2:CONNECTOR  1:PARAMETER   - should be set to  1:TRANSMIT SPEED : 19200
2:PARITY BIT: N
3:DATA 8
4:STOP 1
3:COM PORT
1:BASIC – Connector
2:SYSTEM MODE – Connector
 
4:PROTOCAL TYPE
2:BHT-IR Protocol
 
To download the CCPDE program press 2:DOWNLOAD -> 1:FILE and then on the PC send the CCPDE.PD3 file using TSR-tu3a (located in knowledge database) transfer Utility (don’t forget to set the communication Parameters to 19200,N,8,1).   

                
4:SET SYSTEM

                        ->
5:COMMUNICATIONS

                                ->
2:CONNECTOR

                                         ->
1:PARAMETER - should be set to

                                                      
1:TRANSMIT SPEED : 19200

                                                      
2:PARITY BIT: N

                                                      
3:DATA 8 4:STOP 1 3:COM PORT 1:BASIC – Connector 2:SYSTEM MODE – Connector

4:PROTOCAL TYPE 2:BHT-IR Protocol

To download the CCPDE program press 2:DOWNLOAD -> 1:FILE and then on the PC send the CCPDE.PD3 file using TSR-tu3a (located in knowledge database) transfer Utility (don’t forget to set the communication Parameters to 19200,N,8,1).
Line 30: Line 29:
   
1.COLLECT
2.COLLECT COUNT = 1
3.UPLOAD COUNTS
4.DOWNLOAD MASTERFILE
5.DELETE MENU

1.COLLECT 2.COLLECT COUNT = 1 3.UPLOAD COUNTS 4.DOWNLOAD MASTERFILE 5.DELETE MENU

Updating CCPDE program for Denso

The CCPDE program is a program that runs in BHT BASIC, the source file resides in the std/pde directory called ccpde.src.

There is a BHT BASIC compiler, (30 day trial period), located in the knowledge database hardware/pde/denso/bhtdev4t/BASIC/setup.exe. Need to remember to compile program as a BASIC 3.6 and to turn off option to causes errors for undefined variables. Other wise just refer to the manual – also located in the knowledge database. Once compiled this should create a ccpde.pd3 file.

To download the program onto the PDE Unit hold down SF, 1 and PW keys at the same time to get the System Menu.

You may need to setup the communication setting of the PDE unit first.

  • 4:SET SYSTEM
    • -> 5:COMMUNICATIONS

      • -> 2:CONNECTOR

        • -> 1:PARAMETER - should be set to

          • 1:TRANSMIT SPEED : 19200 2:PARITY BIT: N 3:DATA 8 4:STOP 1 3:COM PORT 1:BASIC – Connector 2:SYSTEM MODE – Connector

4:PROTOCAL TYPE 2:BHT-IR Protocol

To download the CCPDE program press 2:DOWNLOAD -> 1:FILE and then on the PC send the CCPDE.PD3 file using TSR-tu3a (located in knowledge database) transfer Utility (don’t forget to set the communication Parameters to 19200,N,8,1).

After the program is downloaded you could call 1:EXECUTE PROGRAM then CCPDE.PD3 or just turn the unit off and back on again will start the CCPDE program giving the following Menu.

1.COLLECT 2.COLLECT COUNT = 1 3.UPLOAD COUNTS 4.DOWNLOAD MASTERFILE 5.DELETE MENU

Updating_PDE_Software (last edited 2013-09-18 06:09:34 by localhost)