Line 10: Line 10:
                4:SET SYSTEM

                        -> 5:COMMUNICATIONS

                                -> 2:CONNECTOR

                                         -> 1:PARAMETER - should be set to

                                                      1:TRANSMIT SPEED : 19200

                                                      2:PARITY BIT: N

                                                      3:DATA 8 4:STOP 1 3:COM PORT 1:BASIC – Connector 2:SYSTEM MODE – Connector
 . 4:SET SYSTEM
  . -> 5:COMMUNICATIONS
   . -> 2:CONNECTOR
    . -> 1:PARAMETER - should be set to
     . 1:TRANSMIT SPEED : 19200
     . 2:PARITY BIT: N
     . 3:DATA 8
     . 4:STOP 1
   . -> 3:COM PORT
   . 1:BASIC – Connector
   . 2:SYSTEM MODE – Connector
Line 30: Line 27:
1.COLLECT 2.COLLECT COUNT = 1 3.UPLOAD COUNTS 4.DOWNLOAD MASTERFILE 5.DELETE MENU                                            1.COLLECT

                                           2.COLLECT COUNT = 1

                                           3.UPLOAD COUNTS

                                           4.DOWNLOAD MASTERFILE

                                           5.DELETE MENU

Updating CCPDE program for Denso

The CCPDE program is a program that runs in BHT BASIC, the source file resides in the std/pde directory called ccpde.src.

There is a BHT BASIC compiler, (30 day trial period), located in the knowledge database hardware/pde/denso/bhtdev4t/BASIC/setup.exe. Need to remember to compile program as a BASIC 3.6 and to turn off option to causes errors for undefined variables. Other wise just refer to the manual – also located in the knowledge database. Once compiled this should create a ccpde.pd3 file.

To download the program onto the PDE Unit hold down SF, 1 and PW keys at the same time to get the System Menu.

You may need to setup the communication setting of the PDE unit first.

  • 4:SET SYSTEM
    • -> 5:COMMUNICATIONS

      • -> 2:CONNECTOR

        • -> 1:PARAMETER - should be set to

          • 1:TRANSMIT SPEED : 19200
          • 2:PARITY BIT: N
          • 3:DATA 8
          • 4:STOP 1
      • -> 3:COM PORT

      • 1:BASIC – Connector
      • 2:SYSTEM MODE – Connector

4:PROTOCAL TYPE 2:BHT-IR Protocol

To download the CCPDE program press 2:DOWNLOAD -> 1:FILE and then on the PC send the CCPDE.PD3 file using TSR-tu3a (located in knowledge database) transfer Utility (don’t forget to set the communication Parameters to 19200,N,8,1).

After the program is downloaded you could call 1:EXECUTE PROGRAM then CCPDE.PD3 or just turn the unit off and back on again will start the CCPDE program giving the following Menu.

  • 1.COLLECT 2.COLLECT COUNT = 1 3.UPLOAD COUNTS 4.DOWNLOAD MASTERFILE 5.DELETE MENU